Subject: Re: CCM3 questions
From: Brian Eaton (eaton@ncar.ucar.edu)
Date: Sun Feb 11 2001 - 07:46:21 MST
Dear Zong-Liang,
The warning about redefining CRAY is not a problem.
The "no such device" message is from a bug in the UNICOS 10.0.0.3 system
software. The workaround is to remove the "-f indef" flag from your load
options.
Brian
On Fri, 9 Feb 2001, Zong-Liang Yang wrote:
> Dear All,
>
> I was trying to use build.cray_ncar.csh (downloaded from
> http://www.cgd.ucar.edu/cms/ccm3/source.shtml the CCM3.6.6 Source Code)
> on NCAR Cray (ouray).
> In compile_log.atm, I have messages saying
>
> Macro "CRAY" has an incompatible redefinition.
>
> #define CRAY
> ^
>
> CC-47 cpp: WARNING File = /tmp/zong/ccm/run/obj/./misc.h, Line = 3
> Macro "CRAY" has an incompatible redefinition.
>
> Once the executable is generated, it cannot be run. For instance, when
> I type atm, a message says "no such device".
>
> This must be easy to fix, but I have no clue at the moment.
> Can anyone help? Thanks.
>
> Zong-Liang
>
> ......................................................................
> Zong-Liang (Leon) Yang, Ph.D. E-mail: liang@hwr.arizona.edu
> Dept of Hydrology and Water Resources __o Phone: (520) 621-8922
> P.O. Box 210011 _-\<, Fax: (520) 621-1422
> The University of Arizona ___________(_)/(_)________________________
> Tucson AZ 85721-0011 URL http://www.hwr.arizona.edu/~liang
> ______________________________Street Address: 1133 E. North Campus Dr.
>
>
>
Brian Eaton | email: eaton@ucar.edu