Subject: Re: Averaging flags
From: Erik Kluzek (erik@ucar.edu)
Date: Mon Feb 12 2001 - 12:33:55 MST
On Mon, 12 Feb 2001, Kenneth P. Bowman wrote:
> Is there any way to change the averaging flags for output variables
> in CCM3.10.11 other than by modifying bldfld.F90?
>
Yes there is! But, unfortunately we didn't seem to document this anywhere.
Basically, you add a descriptor to the fields you are adding in the
namelist to specify what type of averaging you want to take place.
Here's a more detailed description of this feature.
o Per-field averaging flag allowed in namelist via colon separation
of field name from flag. For example, to make the temperature
field instantaneous on tape 2 one would specify:
fincl(2) = 'T:I'
Note that like the field name, the averaging flag is case-sensitive
Thanks
Erik Kluzek, (CGD at NCAR)
National Center for Atmospheric Research
Boulder CO, (off) (303)497-1326 (fax) (303)497-1324
--------- Home page and public PGP key---------------
http://www.cgd.ucar.edu/~erik
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!