Problem with CCM 3.6.6 (T31) blowing up within 2 years ...


Subject: Problem with CCM 3.6.6 (T31) blowing up within 2 years ...
From: Dave Newman (newman@uci.edu)
Date: Fri Mar 01 2002 - 10:11:16 MST


Dear CCM users --

I am having a problem with CCM 3.6.6 blowing up within 2 years, and
wanted to see if anyone was experiencing anything similar, or if anyone
had any suggestions on what may be causing the problem. Here is some
relevant information:

Version: CCM 3.6.6
Res: T31
DIME: 1800 (=30 mins)
Mode: DST_FRC (i.e. no feedbacks)
DIF4: 0.2E17
Machine: SGI

The run stops at NSTEP=28660 (approx day=597, year=1.6) with the message:
CUBYDR: Departure point out of bounds: jcen,icount,pgls= 9, 1726, 1728

I noticed that the Courant limit seemed to be creeping up as well.
Also, I reran exactly the same model/case at T42, and it ran perfectly
fine for several years (well beyond day=597)

Does anyone have any suggestions or comments? Any help would be greatly
appreciated!

Thanks,
Dave Newman
newman@uci.edu

--------------------------------------------------------------

Below is some more detailed info on this run ...

Input data
==========

  dstccm50: CCM 3.6.6 dst-1.0.15: dcr mbl newman test
  User name to build pathnames = newman
  Initial dataset is: JAN1.T31.0198.nc
  Time-variant boundary dataset (sst) is: T31M5079.nc
  Time-variant boundary dataset (ozone) is: ozn.0596.r8.nc

  History file 1 will be a monthly average
  Fields on history file 2 are instantaneous
  Base day,seconds of day = 0 0
  Base date,seconds of date = 101 0
  Elapsed time to end run (NELAPSE) 87600
  Time step in seconds (DTIME) 1800.
  Time filter coefficient (EPS) 0.060
  DEL2 Horizontal diffusion coefficient (DIF2) 0.250E+06
  DEL4 Horizontal diffusion coefficient (DIF4) 0.200E+17
  Number of levels Courant limiter applied 1
  Lowest level for dry adiabatic adjust (NLVDRY) 3
  Frequency of Shortwave Radiation calc. (IRADSW) 2
  Frequency of Longwave Radiation calc. (IRADLW) 2
  Frequency of Absorptivity/Emissivity calc. (IRADAE) 24
  Frequency of SST Initialization calc. (ITSST) 1
  SST dataset will be reused for each model year
  OZONE dataset will be reused for each model year
  Output files will be disposed ASYNCHRONOUSLY
  divergence damper NOT invoked
  global co2 volume mixing ratio = 3.5500000000000001E-4
  number of user advected tracers= 4
  All advected user tracers will be initialized to zero
  Visible optical depth (tauvis) = 0.14000000000000001
  Orbital parameters calculated for given year: 1950 AD

Final output
============

  NSTEP = 28658 8.779757585849342E-05 6.328269167202861E-06 252.587
9.84572E+04 2.387539556912451E+01 1.61 0.32
COURLIM: *** Courant limit exceeded at k,lat= 1 37 (estimate = 1.391),
solution has been truncated to wavenumber 22 ***
  *** Original Courant limit exceeded at k,lat= 1 37 (estimate =
1.391) ***
  NSTEP = 28659 8.781644339713775E-05 6.556245519381330E-06 252.583
9.84572E+04 2.387403670644274E+01 1.86 0.48
COURLIM: *** Courant limit exceeded at k,lat= 1 37 (estimate = 1.405),
solution has been truncated to wavenumber 22 ***
  *** Original Courant limit exceeded at k,lat= 1 37 (estimate =
1.405) ***
  NSTEP = 28660 8.785450835741513E-05 7.065918497627775E-06 252.578
9.84572E+04 2.387370473511656E+01 2.09 0.70
  CUBYDR: Departure point out of bounds: jcen,icount,pgls= 9, 1726, 1728
IOT Trap
Error: thread 1 (pid 2480255) has returned unexpectedly
Received signal 6: Abort or IOT